Heat pumps and air conditioning: mandatory maintenance every two years

Since 2020, heat pumps and air conditioners from 4 to 70 kW must be serviced at least every two years. What the visit covers, who may handle the refrigerant and how to retain these customers.

These pages describe French rules. The translations do not constitute an adaptation to the law of another country.

25 Sept 2026 · 5 min read

The decree of 28 July 2020 extended to thermodynamic systems the maintenance obligation that already applied to boilers. Heat pumps and air conditioners with a rated output of 4 to 70 kW must be serviced at least every two years: air-to-water, air-to-air and ground-source heat pumps, in homes as well as small business premises. This obligation does not apply to systems intended solely to produce hot water for a single dwelling.

As with a boiler, the obligation falls on the occupier: the tenant unless the lease provides otherwise, or the owner-occupier. For a communal installation, the owner or the co-owners’ association must arrange it.

The visit, detailed in an order of 24 July 2020, covers the whole installation: checking the components, cleaning filters and heat exchangers where necessary, checking the refrigerant circuit for leaks, checking settings and proper operation, then advising the customer on using the equipment and possible improvements.

After the service, you give the customer a certificate within fifteen days. It includes your contact details, the installation address, the appliance concerned, the visit date, the work performed and your recommendations. This is the document your customer’s insurer may ask for, and some manufacturers make it a condition of their warranty.

Do not confuse maintenance every two years with the periodic leak check required by the European F-Gas Regulation. Work on refrigerants and the statutory checks concerned must be entrusted to an operator holding the certificates and qualifications required for the refrigerant and operation; simply cleaning the equipment does not authorise handling the refrigerant. For maintenance every two years, the Order of 24 July 2020 provides, where applicable, for checking the sight glass and reading the pressures on the pressure gauges. Regulation (EU) 2024/573 additionally requires periodic checks from 5 tonnes of CO2 equivalent for the gases in Annex I, or 1 kg for those in Annex II, Section 1. Equipment that is hermetically sealed and labelled as such is exempt below 10 tonnes of CO2 equivalent or below 2 kg, depending on the gas family; in a residential building, an exemption also covers such equipment containing less than 3 kg of fluorinated gases. The frequency depends on the charge and whether a leak detection system is present. Check the refrigerant, charge, labelling and qualifications before the work.

For VAT, servicing a heat pump in a home completed more than two years ago is subject to the reduced rate, with the customer’s certification: generally 10 %, or 5.5 % when the appliance meets the technical criteria for the 5.5 % rate.

Two years is a long time: long enough for the customer to forget who installed their heat pump. That longer interval is precisely what makes a reminder valuable. A customer who receives a message from their installer at the right time calls them back; one who does not looks for someone else when the appliance develops a fault.

In Okivo, the heat pump, air-conditioning system or heat-pump water heater is recorded in the customer’s maintenance log, with an editable default interval of two years. A heat-pump water heater serving only one home is not subject to the obligation, but a reminder is still useful. Okivo calculates the due date and, thirty days beforehand, sends the customer a reminder in your name if they have agreed to it. They reply directly to you to arrange the date.

To go further.